{"id":860,"date":"2026-07-24T09:22:57","date_gmt":"2026-07-24T09:22:57","guid":{"rendered":"https:\/\/byqpower.com\/product\/scb13-1250kva-dry-type-power-transformer\/"},"modified":"2026-09-08T06:58:16","modified_gmt":"2026-09-08T06:58:16","slug":"scb13-1250kva-kuru-tip-guc-transformatoru","status":"publish","type":"product","link":"https:\/\/www.byqpower.com\/tr\/product\/scb13-1250kva-dry-type-power-transformer\/","title":{"rendered":"SC(B)13 1250 kVA Kuru Tip G\u00fc\u00e7 Trafosu"},"content":{"rendered":"<p>Orta ve b\u00fcy\u00fck \u00f6l\u00e7ekli g\u00fc\u00e7 da\u011f\u0131t\u0131m senaryolar\u0131nda, y\u00fcksek elektrik t\u00fcketimi, y\u00fcksek g\u00fcvenlik ve \u00e7evre koruma gereksinimleri ve yetersiz ekipman uyarlanabilirli\u011fi gibi ortak end\u00fcstri s\u0131k\u0131nt\u0131 noktalar\u0131 vard\u0131r.Al\u0131c\u0131lar genellikle ekipman kapasitesi ve senaryolar\u0131 aras\u0131ndaki uyumsuzluk ve y\u00fcksek i\u015fletme ve bak\u0131m maliyetleri gibi sorunlarla kar\u015f\u0131 kar\u015f\u0131ya kal\u0131rlar.\u00c7ok senaryolu adaptasyonu sa\u011flamak i\u00e7in Kutu Tipi Trafo Merkezi, Y\u00fcksek Ve Al\u00e7ak Gerilim \u015ealt Cihaz\u0131 ve Elektrik G\u00fc\u00e7 D\u00f6n\u00fc\u015ft\u00fcr\u00fcc\u00fcs\u00fc ile Kombine Fotovoltaik Trafo Merkezine k\u0131yasla, orta ve b\u00fcy\u00fck \u00f6l\u00e7ekli y\u00fck konsantrasyon senaryolar\u0131 i\u00e7in daha uygundur, karars\u0131z g\u00fc\u00e7 kayna\u011f\u0131 ve hantal i\u015fletme ve bak\u0131m gibi sorunlar\u0131 etkili bir \u015fekilde \u00e7\u00f6zebilir, verimli enerji tasarrufu ve g\u00fcvenli ve G\u00fcvenilir G\u00fc\u00e7 Kayna\u011f\u0131 elde edebilir ve uzun vadeli i\u015fletme maliyetlerini azaltabilir.Temel amac\u0131, orta ve b\u00fcy\u00fck \u00f6l\u00e7ekli end\u00fcstriyel, kamu binalar\u0131 ve yeni enerji destekleyici senaryolar i\u00e7in kararl\u0131 voltaj d\u00f6n\u00fc\u015f\u00fcm hizmetleri sunmak, konsantre b\u00fcy\u00fck g\u00fc\u00e7 ekipmanlar\u0131n\u0131n g\u00fc\u00e7 kayna\u011f\u0131 talebini kar\u015f\u0131lamak, g\u00fc\u00e7 da\u011f\u0131t\u0131m sisteminin verimli \u00e7al\u0131\u015fmas\u0131na yard\u0131mc\u0131 olmak ve b\u00fcy\u00fck kapasiteli kuru tip ekipmanlar\u0131n \u00e7ekirdek de\u011ferini g\u00f6stermektir.<\/p>\n<div>\n<p><strong>\u00dcr\u00fcn \u00d6zellikleri :<\/strong><\/p>\n<p>G\u00fc\u00e7l\u00fc adaptasyon ile 1. B\u00fcy\u00fck kapasite.1250 kVA kapasitesi orta ve b\u00fcy\u00fck \u00f6l\u00e7ekli senaryolar i\u00e7in merkezi g\u00fc\u00e7 kayna\u011f\u0131 gereksinimlerini kar\u015f\u0131layabilir.B\u00fcy\u00fck kamu binalar\u0131nda \u00e7oklu end\u00fcstriyel \u00fcretim hatlar\u0131n\u0131n ve \u00e7e\u015fitli Elektrik Ekipmanlar\u0131n\u0131n y\u00fck\u00fcn\u00fc istikrarl\u0131 bir \u015fekilde ta\u015f\u0131yabilir.Yeni enerjiyi geleneksel g\u00fc\u00e7 da\u011f\u0131t\u0131m\u0131yla birle\u015ftiren karma\u015f\u0131k senaryolara uyum sa\u011flayarak Kombine Fotovoltaik Trafo Merkezleri ve Elektrik G\u00fc\u00e7 D\u00f6n\u00fc\u015ft\u00fcr\u00fcc\u00fcleri ile koordineli olarak \u00e7al\u0131\u015fabilir. G\u00fc\u00e7 kayna\u011f\u0131 stabilitesi k\u00fc\u00e7\u00fck kuru tip transformat\u00f6rlerinkinden \u00e7ok daha \u00fcst\u00fcnd\u00fcr.<\/p>\n<p>2. G\u00fcvenli, dayan\u0131kl\u0131 ve kullan\u0131m\u0131 kolay, ya\u011f veya s\u0131z\u0131nt\u0131 olmadan tamamen kapal\u0131 bir epoksi d\u00f6k\u00fcm yap\u0131s\u0131n\u0131 benimser.Ya\u011fa Dald\u0131r\u0131lm\u0131\u015f Transformat\u00f6rlerde ya\u011f s\u0131z\u0131nt\u0131s\u0131n\u0131n neden oldu\u011fu g\u00fcvenlik ve \u00e7evresel tehlikelerden ka\u00e7\u0131n\u0131r. Karma\u015f\u0131k yang\u0131ndan korunma \u00f6nlemlerine gerek kalmadan do\u011frudan i\u00e7 ve d\u0131\u015f g\u00fc\u00e7 da\u011f\u0131t\u0131m odalar\u0131na kurulabilir. G\u00fcnl\u00fck bak\u0131m yaln\u0131zca basit toz giderme gerektirir ve operasyon i\u00e7in profesyonel bir ekip gerekmez. Bu, al\u0131c\u0131 i\u00e7in sat\u0131n alma sonras\u0131 yat\u0131r\u0131m\u0131 \u00f6nemli \u00f6l\u00e7\u00fcde azalt\u0131r.<\/p>\n<div>\n<p><strong>\u0130pu\u00e7lar\u0131:<\/strong><\/p>\n<p>1. Ekipman kurulumu s\u0131ras\u0131nda, d\u00fczg\u00fcn \u0131s\u0131 da\u011f\u0131l\u0131m\u0131 sa\u011flamak i\u00e7in Kutu Tipi Trafo Merkezi ve Y\u00fcksek Ve Al\u00e7ak Gerilim \u015ealt Cihaz\u0131ndan uygun bir mesafeyi koruyun.Elektrik G\u00fc\u00e7 D\u00f6n\u00fc\u015ft\u00fcr\u00fcc\u00fcs\u00fc ile ba\u011flant\u0131 kurarken, istikrarl\u0131 koordineli \u00e7al\u0131\u015fmay\u0131 sa\u011flamak i\u00e7in aray\u00fcz parametrelerinde \u00f6nceden hata ay\u0131klay\u0131n.<\/p>\n<p>2. Uzun s\u00fcreli \u00e7al\u0131\u015fma s\u0131ras\u0131nda, ekipman\u0131n y\u00fcksek s\u0131cakl\u0131k ve y\u00fcksek nem ortamlar\u0131na maruz kalmas\u0131n\u0131 \u00f6nlemek gerekir. A\u015f\u0131r\u0131 y\u00fck nedeniyle ekipman\u0131n servis \u00f6mr\u00fc \u00fczerindeki etkiyi \u00f6nlemek i\u00e7in her 12 ayda bir sar\u0131m s\u0131cakl\u0131\u011f\u0131 ve kablolama ko\u015fullar\u0131n\u0131n rutin bir incelemesini yap\u0131n.<\/p>\n<div>\n<p><strong>SSS (S\u0131k\u00e7a Sorulan Sorular):<\/strong><\/p>\n<p>1. Bu Kuru Tip Trafonun 1250 kVA kapasitesi i\u00e7in, hangi \u00f6zel senaryolarda kullan\u0131ma uygundur? cevap: Esas olarak b\u00fcy\u00fck end\u00fcstriyel tesis ana da\u011f\u0131t\u0131m\u0131, b\u00fcy\u00fck kamu binalar\u0131 (kongre merkezleri, spor mekanlar\u0131), b\u00f6lgesel da\u011f\u0131t\u0131m merkezleri ve yeni enerji i\u00e7in elektrik santralleri i\u00e7in uygulanabilir, konsantre b\u00fcy\u00fck g\u00fc\u00e7l\u00fc ekipman i\u00e7in g\u00fc\u00e7 kayna\u011f\u0131 gereksinimlerini kar\u015f\u0131lar ve son derece g\u00fc\u00e7l\u00fc uyarlanabilirli\u011fe sahiptir.<\/p>\n<p>2. Ekipman garanti s\u00fcresi ne kadard\u0131r? ar\u0131za durumunda nas\u0131l sa\u011flan\u0131r? cevap: Garanti s\u00fcresi 18 ayd\u0131r garanti s\u00fcresi boyunca insan kaynakl\u0131 olmayan ar\u0131zalar \u00fccretsiz olarak tamir edilip de\u011fi\u015ftirilebilir.sat\u0131\u015f sonras\u0131 ekip, sorunu ele almak ve ekipman ar\u0131zas\u0131n\u0131n projenin normal \u00e7al\u0131\u015fmas\u0131n\u0131 etkilemesini \u00f6nlemek i\u00e7in e\u015f zamanl\u0131 olarak teknik rehberlik sa\u011flamak i\u00e7in 48 saat i\u00e7inde sahaya varacakt\u0131r.<\/p>\n<p>3. Ya\u011f Dald\u0131rma Transformat\u00f6rleri ile kar\u015f\u0131la\u015ft\u0131r\u0131ld\u0131\u011f\u0131nda, bu ekipman\u0131n enerji tasarrufu etkisi nas\u0131ld\u0131r? Cevap: Ayn\u0131 kapasitedeki Ya\u011f Dald\u0131rma Transformat\u00f6rlerine k\u0131yasla y\u00fcks\u00fcz kay\u0131p 25%'den daha fazla azal\u0131r ve y\u00fck kayb\u0131 yakla\u015f\u0131k 15% azal\u0131r. Uzun vadede b\u00fcy\u00fck miktarda elektrik tasarrufu sa\u011flayabilir ve \u00f6zellikle orta ve b\u00fcy\u00fck \u00f6l\u00e7ekli senaryolarda uzun vadeli s\u00fcrekli g\u00fc\u00e7 kayna\u011f\u0131 i\u00e7in uygundur.<\/p>\n<div>\n<div>\n<div class=\"product-spec-table\">\n<table>\n<caption>Kuru Tip Trafo Teknik \u00d6zellikleri<\/caption>\n<thead>\n<tr>\n<th>Model<\/th>\n<th>Nominal Kapasite (kVA)<\/th>\n<th>Ba\u011flant\u0131 Grubu<\/th>\n<th>HV Anma Gerilimi (kV)<\/th>\n<th>Dokunma Aral\u0131\u011f\u0131<\/th>\n<th>LV Anma Gerilimi (kV)<\/th>\n<th>Y\u00fcks\u00fcz Kay\u0131p (kW)<\/th>\n<th>Y\u00fck Kayb\u0131 (kW)<\/th>\n<th>Y\u00fcks\u00fcz Ak\u0131m (%)<\/th>\n<th>K\u0131sa Devre Empedans\u0131 (%)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>SC(B)30<\/td>\n<td>30<\/td>\n<td>Dyn11 \/ Yyn0<\/td>\n<td>6 \/ 6.3 \/ 6.6 \/ 10 \/ 10.5 \/ 11<\/td>\n<td>\u00b12,5% \/ \u00b15%<\/td>\n<td>0.4<\/td>\n<td>0.13<\/td>\n<td>0.64<\/td>\n<td>2.0<\/td>\n<td>4.0<\/td>\n<\/tr>\n<tr>\n<td>SC(B)50<\/td>\n<td>50<\/td>\n<td>Dyn11 \/ Yyn0<\/td>\n<td>6 \/ 6.3 \/ 6.6 \/ 10 \/ 10.5 \/ 11<\/td>\n<td>\u00b12,5% \/ \u00b15%<\/td>\n<td>0.4<\/td>\n<td>0.185<\/td>\n<td>0.9<\/td>\n<td>2.0<\/td>\n<td>4.0<\/td>\n<\/tr>\n<tr>\n<td>SC(B)80<\/td>\n<td>80<\/td>\n<td>Dyn11 \/ Yyn0<\/td>\n<td>6 \/ 6.3 \/ 6.6 \/ 10 \/ 10.5 \/ 11<\/td>\n<td>\u00b12,5% \/ \u00b15%<\/td>\n<td>0.4<\/td>\n<td>0.25<\/td>\n<td>1.24<\/td>\n<td>1.5<\/td>\n<td>4.0<\/td>\n<\/tr>\n<tr>\n<td>SC(B)100<\/td>\n<td>100<\/td>\n<td>Dyn11 \/ Yyn0<\/td>\n<td>6 \/ 6.3 \/ 6.6 \/ 10 \/ 10.5 \/ 11<\/td>\n<td>\u00b12,5% \/ \u00b15%<\/td>\n<td>0.4<\/td>\n<td>0.27<\/td>\n<td>1.415<\/td>\n<td>1.5<\/td>\n<td>4.0<\/td>\n<\/tr>\n<tr>\n<td>SC(B)125<\/td>\n<td>125<\/td>\n<td>Dyn11 \/ Yyn0<\/td>\n<td>6 \/ 6.3 \/ 6.6 \/ 10 \/ 10.5 \/ 11<\/td>\n<td>\u00b12,5% \/ \u00b15%<\/td>\n<td>0.4<\/td>\n<td>0.32<\/td>\n<td>1.665<\/td>\n<td>1.3<\/td>\n<td>4.0<\/td>\n<\/tr>\n<tr>\n<td>SC(B)160<\/td>\n<td>160<\/td>\n<td>Dyn11 \/ Yyn0<\/td>\n<td>6 \/ 6.3 \/ 6.6 \/ 10 \/ 10.5 \/ 11<\/td>\n<td>\u00b12,5% \/ \u00b15%<\/td>\n<td>0.4<\/td>\n<td>0.365<\/td>\n<td>1.915<\/td>\n<td>1.3<\/td>\n<td>4.0<\/td>\n<\/tr>\n<tr>\n<td>SC(B)200<\/td>\n<td>200<\/td>\n<td>Dyn11 \/ Yyn0<\/td>\n<td>6 \/ 6.3 \/ 6.6 \/ 10 \/ 10.5 \/ 11<\/td>\n<td>\u00b12,5% \/ \u00b15%<\/td>\n<td>0.4<\/td>\n<td>0.42<\/td>\n<td>2.275<\/td>\n<td>1.1<\/td>\n<td>4.0<\/td>\n<\/tr>\n<tr>\n<td>SC(B)250<\/td>\n<td>250<\/td>\n<td>Dyn11 \/ Yyn0<\/td>\n<td>6 \/ 6.3 \/ 6.6 \/ 10 \/ 10.5 \/ 11<\/td>\n<td>\u00b12,5% \/ \u00b15%<\/td>\n<td>0.4<\/td>\n<td>0.49<\/td>\n<td>2.485<\/td>\n<td>1.1<\/td>\n<td>4.0<\/td>\n<\/tr>\n<tr>\n<td>SB(B)315<\/td>\n<td>315<\/td>\n<td>Dyn11 \/ Yyn0<\/td>\n<td>6 \/ 6.3 \/ 6.6 \/ 10 \/ 10.5 \/ 11<\/td>\n<td>\u00b12,5% \/ \u00b15%<\/td>\n<td>0.4<\/td>\n<td>0.6<\/td>\n<td>3.125<\/td>\n<td>1.0<\/td>\n<td>4.0<\/td>\n<\/tr>\n<tr>\n<td>SC(B)400<\/td>\n<td>400<\/td>\n<td>Dyn11 \/ Yyn0<\/td>\n<td>6 \/ 6.3 \/ 6.6 \/ 10 \/ 10.5 \/ 11<\/td>\n<td>\u00b12,5% \/ \u00b15%<\/td>\n<td>0.4<\/td>\n<td>0.665<\/td>\n<td>3.59<\/td>\n<td>1.0<\/td>\n<td>4.0<\/td>\n<\/tr>\n<tr>\n<td>SC(B)500<\/td>\n<td>500<\/td>\n<td>Dyn11 \/ Yyn0<\/td>\n<td>6 \/ 6.3 \/ 6.6 \/ 10 \/ 10.5 \/ 11<\/td>\n<td>\u00b12,5% \/ \u00b15%<\/td>\n<td>0.4<\/td>\n<td>0.79<\/td>\n<td>4.39<\/td>\n<td>1.0<\/td>\n<td>4.0<\/td>\n<\/tr>\n<tr>\n<td>SC(B)630<\/td>\n<td>630<\/td>\n<td>Dyn11 \/ Yyn0<\/td>\n<td>6 \/ 6.3 \/ 6.6 \/ 10 \/ 10.5 \/ 11<\/td>\n<td>\u00b12,5% \/ \u00b15%<\/td>\n<td>0.4<\/td>\n<td>0.91<\/td>\n<td>5.29<\/td>\n<td>0.85<\/td>\n<td>4.0<\/td>\n<\/tr>\n<tr>\n<td>SC(B)630<\/td>\n<td>630<\/td>\n<td>Dyn11 \/ Yyn0<\/td>\n<td>6 \/ 6.3 \/ 6.6 \/ 10 \/ 10.5 \/ 11<\/td>\n<td>\u00b12,5% \/ \u00b15%<\/td>\n<td>0.4<\/td>\n<td>0.885<\/td>\n<td>5.365<\/td>\n<td>0.85<\/td>\n<td>6.0<\/td>\n<\/tr>\n<tr>\n<td>SC(B)800<\/td>\n<td>800<\/td>\n<td>Dyn11 \/ Yyn0<\/td>\n<td>6 \/ 6.3 \/ 6.6 \/ 10 \/ 10.5 \/ 11<\/td>\n<td>\u00b12,5% \/ \u00b15%<\/td>\n<td>0.4<\/td>\n<td>1.035<\/td>\n<td>6.265<\/td>\n<td>0.85<\/td>\n<td>6.0<\/td>\n<\/tr>\n<tr>\n<td>SC(B)1000<\/td>\n<td>1000<\/td>\n<td>Dyn11 \/ Yyn0<\/td>\n<td>6 \/ 6.3 \/ 6.6 \/ 10 \/ 10.5 \/ 11<\/td>\n<td>\u00b12,5% \/ \u00b15%<\/td>\n<td>0.4<\/td>\n<td>1.205<\/td>\n<td>7.315<\/td>\n<td>0.85<\/td>\n<td>6.0<\/td>\n<\/tr>\n<tr>\n<td>SC(B)1250<\/td>\n<td>1250<\/td>\n<td>Dyn11 \/ Yyn0<\/td>\n<td>6 \/ 6.3 \/ 6.6 \/ 10 \/ 10.5 \/ 11<\/td>\n<td>\u00b12,5% \/ \u00b15%<\/td>\n<td>0.4<\/td>\n<td>1.42<\/td>\n<td>8.72<\/td>\n<td>0.85<\/td>\n<td>6.0<\/td>\n<\/tr>\n<tr>\n<td>SC(B)1600<\/td>\n<td>1600<\/td>\n<td>Dyn11 \/ Yyn0<\/td>\n<td>6 \/ 6.3 \/ 6.6 \/ 10 \/ 10.5 \/ 11<\/td>\n<td>\u00b12,5% \/ \u00b15%<\/td>\n<td>0.4<\/td>\n<td>1.665<\/td>\n<td>10.555<\/td>\n<td>0.85<\/td>\n<td>6.0<\/td>\n<\/tr>\n<tr>\n<td>SC(B)2000<\/td>\n<td>2000<\/td>\n<td>Dyn11 \/ Yyn0<\/td>\n<td>6 \/ 6.3 \/ 6.6 \/ 10 \/ 10.5 \/ 11<\/td>\n<td>\u00b12,5% \/ \u00b15%<\/td>\n<td>0.4<\/td>\n<td>2.075<\/td>\n<td>13.005<\/td>\n<td>0.7<\/td>\n<td>6.0<\/td>\n<\/tr>\n<tr>\n<td>SC(B)2500<\/td>\n<td>2500<\/td>\n<td>Dyn11 \/ Yyn0<\/td>\n<td>6 \/ 6.3 \/ 6.6 \/ 10 \/ 10.5 \/ 11<\/td>\n<td>\u00b12,5% \/ \u00b15%<\/td>\n<td>0.4<\/td>\n<td>2.45<\/td>\n<td>15.445<\/td>\n<td>0.7<\/td>\n<td>6.0<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Orta ve b\u00fcy\u00fck \u00f6l\u00e7ekli g\u00fc\u00e7 da\u011f\u0131t\u0131m senaryolar\u0131nda, y\u00fcksek elektrik t\u00fcketimi, y\u00fcksek g\u00fcvenlik ve \u00e7evre koruma gereklilikleri ve yetersiz ekipman uyarlanabilirli\u011fi gibi ortak end\u00fcstri s\u0131k\u0131nt\u0131 noktalar\u0131 vard\u0131r.<\/p>","protected":false},"featured_media":776,"template":"","meta":{"rank_math_title":"SC(B)13 1250 kVA Dry-Type Power Transformer | Heavy Loads","rank_math_description":"SC(B)13 1250 kVA Dry-Type Power Transformer supplies concentrated industrial and solar loads with energy efficiency, oil-free safety and adaptable integration.","rank_math_canonical_url":"","rank_math_focus_keyword":"SC(B)13 1250 kVA Dry-Type Power Transformer"},"product_brand":[],"product_cat":[28],"product_tag":[],"class_list":["post-860","product","type-product","status-publish","has-post-thumbnail","product_cat-dry-type-transformers","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/www.byqpower.com\/tr\/wp-json\/wp\/v2\/product\/860","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.byqpower.com\/tr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.byqpower.com\/tr\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.byqpower.com\/tr\/wp-json\/wp\/v2\/media\/776"}],"wp:attachment":[{"href":"https:\/\/www.byqpower.com\/tr\/wp-json\/wp\/v2\/media?parent=860"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.byqpower.com\/tr\/wp-json\/wp\/v2\/product_brand?post=860"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.byqpower.com\/tr\/wp-json\/wp\/v2\/product_cat?post=860"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.byqpower.com\/tr\/wp-json\/wp\/v2\/product_tag?post=860"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}