{"id":898,"date":"2026-07-24T09:23:00","date_gmt":"2026-07-24T09:23:00","guid":{"rendered":"https:\/\/byqpower.com\/product\/2000kva-20kv-oil-immersed-power-transformer\/"},"modified":"2026-09-08T06:58:17","modified_gmt":"2026-09-08T06:58:17","slug":"transformador-de-potencia-sumergido-en-aceite-de-2000kva-20kv","status":"publish","type":"product","link":"https:\/\/www.byqpower.com\/es\/product\/2000kva-20kv-oil-immersed-power-transformer\/","title":{"rendered":"Transformador de potencia con inmersi\u00f3n en aceite de 2000 kVA y 20 kV"},"content":{"rendered":"<p><strong>Transformador de potencia sumergido en aceite de 2000 kVA 20 kV<\/strong><\/p>\n<p>Este transformador de potencia de gran capacidad est\u00e1 especialmente dise\u00f1ado para grandes bases industriales, nuevas ciudades industriales y proyectos regionales de suministro de energ\u00eda centralizada. Estos proyectos suelen tener grandes bases de consumo de electricidad y cargas concentradas. Los equipos de distribuci\u00f3n convencionales a menudo no pueden cumplir con los requisitos de operaci\u00f3n a largo plazo en condiciones de alto voltaje de 20 kV. El transformador de potencia sumergido en aceite de 20 kV y 2000 kVA est\u00e1 dise\u00f1ado para escenarios de gran consumo de energ\u00eda de alta carga y es adecuado para grandes parques manufactureros, \u00e1reas mineras, subestaciones urbanas suburbanas de alto voltaje y nuevos proyectos de soporte de energ\u00eda a gran escala. El equipo se puede integrar en la soluci\u00f3n de distribuci\u00f3n completa de la subestaci\u00f3n tipo caja y coordinarse con aparamenta de alto y bajo voltaje para planificar el dise\u00f1o del circuito de alto voltaje, de acuerdo con las normas de construcci\u00f3n de proyectos de transmisi\u00f3n y distribuci\u00f3n de energ\u00eda de alto voltaje.<\/p>\n<p>En una arquitectura de consumo de energ\u00eda diversificada, este equipo se puede combinar de manera flexible con el mismo tipo de transformador sumergido en aceite y unidades de tipo seco para redes. Con la ayuda del Convertidor de Energ\u00eda El\u00e9ctrica para estabilizaci\u00f3n y regulaci\u00f3n de voltaje, puede conectarse sin problemas a Subestaciones Fotovoltaicas Combinadas, logrando un suministro de energ\u00eda complementario entre la red el\u00e9ctrica industrial y la generaci\u00f3n distribuida, ayudando a las empresas a completar la actualizaci\u00f3n de sus sistemas de distribuci\u00f3n y reduciendo los costos posteriores de operaci\u00f3n y mantenimiento y renovaci\u00f3n.<\/p>\n<p><strong>Ventaja central<\/strong><br \/>\nEl grado de aislamiento general es compatible con el est\u00e1ndar de alto voltaje de 20 kV. Tiene capacidad suficiente para la transmisi\u00f3n de alta potencia y puede soportar suavemente el funcionamiento continuo a plena carga, as\u00ed como cargas de impacto intermitentes. El estado operativo es estable y la p\u00e9rdida de energ\u00eda est\u00e1 bien controlada.<br \/>\nEl cuerpo de caja engrosado se combina con un proceso completamente sellado, proporcionando una estructura estable que es resistente a la deformaci\u00f3n. A\u00edsla la humedad, el polvo y los medios corrosivos, tiene una gran adaptabilidad ambiental y puede implementarse en diversos entornos, como estaciones exteriores y salas de distribuci\u00f3n interiores.<\/p>\n<p><strong>Consejos de operaci\u00f3n y mantenimiento:<\/strong><br \/>\nAl instalar el equipo, se deben reservar suficientes canales de disipaci\u00f3n de calor para mantener la circulaci\u00f3n del aire a su alrededor. Evite ambientes cerrados de alta temperatura para reducir el envejecimiento y el desgaste a largo plazo del equipo.<br \/>\nLas inspecciones anuales de rutina se centran en los componentes de enfriamiento y sellado del circuito de aceite. Las inspecciones simples pueden mantener el equipo en condiciones operativas estables a largo plazo, con un umbral operativo bajo.<\/p>\n<p><strong>Preguntas y respuestas<\/strong><br \/>\nP1: \u00bfSe puede ajustar de manera flexible la posterior ampliaci\u00f3n y renovaci\u00f3n de capacidad de grandes transformadores de alto voltaje?<br \/>\nR1: Los par\u00e1metros generales est\u00e1n estandarizados y las interfaces de los circuitos son muy vers\u00e1tiles. Durante la posterior ampliaci\u00f3n de la carga del parque y la renovaci\u00f3n de las l\u00edneas de distribuci\u00f3n, se puede integrar directamente en el nuevo sistema sin necesidad de sustituci\u00f3n general de equipos y tiene buena escalabilidad.<\/p>\n<p>P2: Para los modelos de alta potencia que funcionan continuamente durante mucho tiempo, \u00bfest\u00e1 completo el dise\u00f1o de protecci\u00f3n de seguridad?<br \/>\nR2: Est\u00e1 equipado con m\u00faltiples estructuras de protecci\u00f3n y el rendimiento del amortiguador de enfriamiento enfriado por aceite es excelente. Puede amortiguar fluctuaciones instant\u00e1neas de carga y evitar problemas comunes como sobrecarga y sobrecalentamiento, cumpliendo con los est\u00e1ndares industriales de uso seguro de energ\u00eda a largo plazo.<\/p>\n<p>P3: En comparaci\u00f3n con los modelos de capacidad media y peque\u00f1a, \u00bfcu\u00e1les son las principales ventajas de los equipos refrigerados por aceite de gran capacidad?<br \/>\nR3: Tiene una capacidad de carga centralizada m\u00e1s s\u00f3lida y una sola unidad puede cubrir un \u00e1rea grande para el suministro de energ\u00eda, reduciendo la cantidad de equipos e inversi\u00f3n en terrenos, y teniendo costos de distribuci\u00f3n integrales m\u00e1s bajos, lo que la hace m\u00e1s adecuada para la planificaci\u00f3n unificada del suministro de energ\u00eda para grandes \u00e1reas.<\/p>\n<div>\n<div>\n<div class=\"product-spec-table\">\n<table>\n<caption>Especificaciones de eficiencia energ\u00e9tica del transformador sumergido en aceite de 20 kV<\/caption>\n<thead>\n<tr>\n<th>Capacidad nominal (kVA)<\/th>\n<th>Tensi\u00f3n nominal de alta tensi\u00f3n (kV)<\/th>\n<th>Rango de roscado HV<\/th>\n<th>Tensi\u00f3n nominal de BT (kV)<\/th>\n<th>Grupo vectorial<\/th>\n<th>Nivel 1 Sin P\u00e9rdida de Carga (kW)<\/th>\n<th>P\u00e9rdida de carga de nivel 1 (kW)<\/th>\n<th>Nivel 2 Sin P\u00e9rdida de Carga (kW)<\/th>\n<th>P\u00e9rdida de carga de nivel 2 (kW)<\/th>\n<th>Nivel 3 Sin P\u00e9rdida de Carga (kW)<\/th>\n<th>P\u00e9rdida de carga de nivel 3 (kW)<\/th>\n<th>Impedancia de cortocircuito (%)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>30<\/td>\n<td>20<\/td>\n<td>\u00b15%<\/td>\n<td>0.4<\/td>\n<td>Dyn11 \/ Yzn11 \/ Yyn0<\/td>\n<td>0.08<\/td>\n<td>0.621\/0.594<\/td>\n<td>0.08<\/td>\n<td>0.690\/0.660<\/td>\n<td>0.1<\/td>\n<td>0.690\/0.660<\/td>\n<td>5.5<\/td>\n<\/tr>\n<tr>\n<td>50<\/td>\n<td>20<\/td>\n<td>\u00b15%<\/td>\n<td>0.4<\/td>\n<td>Dyn11 \/ Yzn11 \/ Yyn0<\/td>\n<td>0.104<\/td>\n<td>0.909\/0.864<\/td>\n<td>0.104<\/td>\n<td>1.010\/0.960<\/td>\n<td>0.13<\/td>\n<td>1.010\/0.960<\/td>\n<td>5.5<\/td>\n<\/tr>\n<tr>\n<td>68<\/td>\n<td>20<\/td>\n<td>\u00b15%<\/td>\n<td>0.4<\/td>\n<td>Dyn11 \/ Yzn11 \/ Yyn0<\/td>\n<td>0.12<\/td>\n<td>1.080\/1.040<\/td>\n<td>0.12<\/td>\n<td>1.200\/1.150<\/td>\n<td>0.15<\/td>\n<td>1.200\/1.150<\/td>\n<td>5.5<\/td>\n<\/tr>\n<tr>\n<td>80<\/td>\n<td>20<\/td>\n<td>\u00b15%<\/td>\n<td>0.4<\/td>\n<td>Dyn11 \/ Yzn11 \/ Yyn0<\/td>\n<td>0.144<\/td>\n<td>1.290\/1.230<\/td>\n<td>0.144<\/td>\n<td>1.440\/1.370<\/td>\n<td>0.18<\/td>\n<td>1.440\/1.370<\/td>\n<td>5.5<\/td>\n<\/tr>\n<tr>\n<td>100<\/td>\n<td>20<\/td>\n<td>\u00b15%<\/td>\n<td>0.4<\/td>\n<td>Dyn11 \/ Yzn11 \/ Yyn0<\/td>\n<td>0.16<\/td>\n<td>1.560\/1.490<\/td>\n<td>0.16<\/td>\n<td>1.730\/1.650<\/td>\n<td>0.2<\/td>\n<td>1.730\/1.650<\/td>\n<td>5.5<\/td>\n<\/tr>\n<tr>\n<td>125<\/td>\n<td>20<\/td>\n<td>\u00b15%<\/td>\n<td>0.4<\/td>\n<td>Dyn11 \/ Yzn11 \/ Yyn0<\/td>\n<td>0.192<\/td>\n<td>1.870\/1.780<\/td>\n<td>0.192<\/td>\n<td>2.080\/1.980<\/td>\n<td>0.24<\/td>\n<td>2.080\/1.980<\/td>\n<td>5.5<\/td>\n<\/tr>\n<tr>\n<td>160<\/td>\n<td>20<\/td>\n<td>\u00b15%<\/td>\n<td>0.4<\/td>\n<td>Dyn11 \/ Yzn11 \/ Yyn0<\/td>\n<td>0.232<\/td>\n<td>2.290\/2.180<\/td>\n<td>0.232<\/td>\n<td>2.540\/2.420<\/td>\n<td>0.29<\/td>\n<td>2.540\/2.420<\/td>\n<td>5.5<\/td>\n<\/tr>\n<tr>\n<td>200<\/td>\n<td>20<\/td>\n<td>\u00b15%<\/td>\n<td>0.4<\/td>\n<td>Dyn11 \/ Yzn11 \/ Yyn0<\/td>\n<td>0.272<\/td>\n<td>2.700\/2.570<\/td>\n<td>0.272<\/td>\n<td>3.000\/2.860<\/td>\n<td>0.34<\/td>\n<td>3.000\/2.860<\/td>\n<td>5.5<\/td>\n<\/tr>\n<tr>\n<td>250<\/td>\n<td>20<\/td>\n<td>\u00b15%<\/td>\n<td>0.4<\/td>\n<td>Dyn11 \/ Yzn11 \/ Yyn0<\/td>\n<td>0.32<\/td>\n<td>3.170\/3.020<\/td>\n<td>0.32<\/td>\n<td>3.520\/3.350<\/td>\n<td>0.4<\/td>\n<td>3.520\/3.350<\/td>\n<td>5.5<\/td>\n<\/tr>\n<tr>\n<td>315<\/td>\n<td>20<\/td>\n<td>\u00b15%<\/td>\n<td>0.4<\/td>\n<td>Dyn11 \/ Yzn11 \/ Yyn0<\/td>\n<td>0.384<\/td>\n<td>3.79\/3.61<\/td>\n<td>0.384<\/td>\n<td>4.21\/4.01<\/td>\n<td>0.48<\/td>\n<td>4.21\/4.01<\/td>\n<td>5.5<\/td>\n<\/tr>\n<tr>\n<td>400<\/td>\n<td>20<\/td>\n<td>\u00b15%<\/td>\n<td>0.4<\/td>\n<td>Dyn11 \/ Yzn11 \/ Yyn0<\/td>\n<td>0.456<\/td>\n<td>4.47\/4.26<\/td>\n<td>0.456<\/td>\n<td>4.97\/4.73<\/td>\n<td>0.57<\/td>\n<td>4.97\/4.73<\/td>\n<td>5.5<\/td>\n<\/tr>\n<tr>\n<td>500<\/td>\n<td>20<\/td>\n<td>\u00b15%<\/td>\n<td>0.4<\/td>\n<td>Dyn11 \/ Yzn11 \/ Yyn0<\/td>\n<td>0.544<\/td>\n<td>5.35\/5.09<\/td>\n<td>0.544<\/td>\n<td>5.94\/5.66<\/td>\n<td>0.68<\/td>\n<td>5.94\/5.66<\/td>\n<td>5.5<\/td>\n<\/tr>\n<tr>\n<td>630<\/td>\n<td>20<\/td>\n<td>\u00b15%<\/td>\n<td>0.4<\/td>\n<td>Dyn11 \/ Yzn11 \/ Yyn0<\/td>\n<td>0.648<\/td>\n<td>6.140<\/td>\n<td>0.648<\/td>\n<td>6.82<\/td>\n<td>0.81<\/td>\n<td>6.82<\/td>\n<td>6.0<\/td>\n<\/tr>\n<tr>\n<td>800<\/td>\n<td>20<\/td>\n<td>\u00b15%<\/td>\n<td>0.4<\/td>\n<td>Dyn11 \/ Yzn11 \/ Yyn0<\/td>\n<td>0.784<\/td>\n<td>7.430<\/td>\n<td>0.784<\/td>\n<td>8.25<\/td>\n<td>0.98<\/td>\n<td>8.25<\/td>\n<td>6.0<\/td>\n<\/tr>\n<tr>\n<td>1000<\/td>\n<td>20<\/td>\n<td>\u00b15%<\/td>\n<td>0.4<\/td>\n<td>Dyn11 \/ Yzn11 \/ Yyn0<\/td>\n<td>0.92<\/td>\n<td>10.200<\/td>\n<td>0.92<\/td>\n<td>11.3<\/td>\n<td>1.15<\/td>\n<td>11.30<\/td>\n<td>6.0<\/td>\n<\/tr>\n<tr>\n<td>1250<\/td>\n<td>20<\/td>\n<td>\u00b15%<\/td>\n<td>0.4<\/td>\n<td>Dyn11 \/ Yzn11 \/ Yyn0<\/td>\n<td>1.1<\/td>\n<td>11.900<\/td>\n<td>1.1<\/td>\n<td>13.2<\/td>\n<td>1.38<\/td>\n<td>13.20<\/td>\n<td>6.0<\/td>\n<\/tr>\n<tr>\n<td>1600<\/td>\n<td>20<\/td>\n<td>\u00b15%<\/td>\n<td>0.4<\/td>\n<td>Dyn11 \/ Yzn11 \/ Yyn0<\/td>\n<td>1.33<\/td>\n<td>14.400<\/td>\n<td>1.33<\/td>\n<td>16<\/td>\n<td>1.66<\/td>\n<td>16.00<\/td>\n<td>6.0<\/td>\n<\/tr>\n<tr>\n<td>2000<\/td>\n<td>20<\/td>\n<td>\u00b15%<\/td>\n<td>0.4<\/td>\n<td>Dyn11 \/ Yzn11 \/ Yyn0<\/td>\n<td>1.56<\/td>\n<td>17.200<\/td>\n<td>1.56<\/td>\n<td>19.1<\/td>\n<td>1.95<\/td>\n<td>19.10<\/td>\n<td>6.0<\/td>\n<\/tr>\n<tr>\n<td>3000<\/td>\n<td>20<\/td>\n<td>\u00b15%<\/td>\n<td>0.4<\/td>\n<td>Dyn11 \/ Yzn11 \/ Yyn0<\/td>\n<td>1.87<\/td>\n<td>20.000<\/td>\n<td>1.87<\/td>\n<td>22.2<\/td>\n<td>2.34<\/td>\n<td>22.20<\/td>\n<td>6.0<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Este transformador de potencia de gran capacidad est\u00e1 especialmente dise\u00f1ado para grandes bases industriales, nuevas ciudades industriales y proyectos regionales de suministro de energ\u00eda centralizado. Estos proyectos suelen tener grandes bases de consumo de electricidad y cargas concentradas.<\/p>","protected":false},"featured_media":683,"template":"","meta":{"rank_math_title":"2000 kVA 20 kV Oil-Immersed Power Transformer | Heavy Duty","rank_math_description":"2000 kVA 20 kV Oil-Immersed Power Transformer for industrial bases, mines and new energy projects, with full-load stability and a sealed protective enclosure.","rank_math_canonical_url":"","rank_math_focus_keyword":"2000 kVA 20 kV Oil-Immersed Power Transformer"},"product_brand":[],"product_cat":[29],"product_tag":[],"class_list":["post-898","product","type-product","status-publish","has-post-thumbnail","product_cat-oil-immersed-transformers","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/www.byqpower.com\/es\/wp-json\/wp\/v2\/product\/898","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.byqpower.com\/es\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.byqpower.com\/es\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.byqpower.com\/es\/wp-json\/wp\/v2\/media\/683"}],"wp:attachment":[{"href":"https:\/\/www.byqpower.com\/es\/wp-json\/wp\/v2\/media?parent=898"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.byqpower.com\/es\/wp-json\/wp\/v2\/product_brand?post=898"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.byqpower.com\/es\/wp-json\/wp\/v2\/product_cat?post=898"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.byqpower.com\/es\/wp-json\/wp\/v2\/product_tag?post=898"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}