{"id":898,"date":"2026-07-24T09:23:00","date_gmt":"2026-07-24T09:23:00","guid":{"rendered":"https:\/\/byqpower.com\/product\/2000kva-20kv-oil-immersed-power-transformer\/"},"modified":"2026-09-08T06:58:17","modified_gmt":"2026-09-08T06:58:17","slug":"2000-kva-20-kv-ol-eingetauchter-leistungstransformator","status":"publish","type":"product","link":"https:\/\/www.byqpower.com\/de\/product\/2000kva-20kv-oil-immersed-power-transformer\/","title":{"rendered":"2000 kVA 20 kV \u00d6lgetrommelter Leistungstransformator"},"content":{"rendered":"<p><strong>2000 kVA 20 kV \u00d6lgetauchter Leistungstransformator<\/strong><\/p>\n<p>Dieser Leistungstransformator mit gro\u00dfer Kapazit\u00e4t ist speziell f\u00fcr gro\u00dfe Industriest\u00fctzpunkte, industrielle Neust\u00e4dte und regionale zentralisierte Stromversorgungsprojekte konzipiert. Diese Projekte verf\u00fcgen typischerweise \u00fcber gro\u00dfe Stromverbrauchsgrundlagen und konzentrierte Lasten. Herk\u00f6mmliche Verteilungsger\u00e4te sind oft nicht in der Lage, die langfristigen Betriebsanforderungen unter 20-kV-Hochspannungsbedingungen zu erf\u00fcllen. Der 2000-kVA-20-kV-\u00d6lstromtransformator ist auf Szenarien mit hohem Stromverbrauch zugeschnitten und eignet sich f\u00fcr gro\u00dfe Produktionsparks, Bergbaugebiete, st\u00e4dtische Vorstadt-Hochspannungsumspannwerke und gro\u00dfe Projekte zur Unterst\u00fctzung neuer Energie Die Ausr\u00fcstung kann in die komplette Verteilungsl\u00f6sung des Box Type Substation integriert und mit Hochspannungsschaltkreis abgestimmt werden, um die Anordnung der Hochspannungsverteilung zu planen.<\/p>\n<p>In einer diversifizierten Stromverbrauchsarchitektur kann diese Ausr\u00fcstung flexibel mit der gleichen Art von \u00d6l-Tauchtransformatoren und Trockeneinheiten zur Vernetzung kombiniert werden. Mit Hilfe des Stromwandlers zur Spannungsstabilisierung und -regulierung kann sie reibungslos an kombinierte Photovoltaik-Umspannwerke angeschlossen werden, wodurch eine komplement\u00e4re Stromversorgung zwischen industriellem Stromnetz und dezentraler Erzeugung erreicht wird, Unternehmen bei der Modernisierung ihrer Verteilungssysteme unterst\u00fctzt werden und die anschlie\u00dfenden Betriebs-, Wartungs- und Renovierungskosten gesenkt werden.<\/p>\n<p><strong>Kernvorteil<\/strong><br \/>\nDie Gesamtd\u00e4mmsorte ist kompatibel mit dem 20-kV-Hochspannungsstandard, sie verf\u00fcgt \u00fcber ausreichende Kapazit\u00e4t f\u00fcr die Hochleistungs\u00fcbertragung und kann den kontinuierlichen Volllastbetrieb sowie intermittierende Sto\u00dfbelastungen reibungslos bew\u00e4ltigen Der Betriebszustand ist stabil und der Energieverlust gut kontrolliert.<br \/>\nDer verdickte Kastenk\u00f6rper wird mit einem vollst\u00e4ndig abgedichteten Prozess kombiniert, wodurch eine stabile Struktur entsteht, die gegen Verformung best\u00e4ndig ist. Er isoliert Feuchtigkeit, Staub und korrosive Medien, verf\u00fcgt \u00fcber eine starke Anpassungsf\u00e4higkeit an die Umwelt und kann in verschiedenen Umgebungen wie Au\u00dfenstationen und Innenverteilerr\u00e4umen eingesetzt werden.<\/p>\n<p><strong>Betriebs - und Wartungstipps:<\/strong><br \/>\nBei der Installation der Ausr\u00fcstung sollten ausreichende W\u00e4rmeableitungskan\u00e4le reserviert werden, um die Luftzirkulation um sie herum aufrechtzuerhalten Vermeiden Sie geschlossene Hochtemperaturumgebungen, um langfristige Alterung und Verschlei\u00df der Ausr\u00fcstung zu reduzieren.<br \/>\nJ\u00e4hrliche Routineinspektionen konzentrieren sich auf die Dichtungs- und K\u00fchlkomponenten des \u00d6lkreislaufs. Einfache Inspektionen k\u00f6nnen die Ausr\u00fcstung in einem langfristig stabilen Betriebszustand mit einer niedrigen Betriebsschwelle halten.<\/p>\n<p><strong>F&amp;A<\/strong><br \/>\nF1: Kann die sp\u00e4tere Kapazit\u00e4tserweiterung und Sanierung gro\u00dfer Hochspannungstransformatoren flexibel angepasst werden?<br \/>\nA1: Die Gesamtparameter sind standardisiert, und die Schaltkreisschnittstellen sind hoch vielseitig, w\u00e4hrend des sp\u00e4teren Ausbaus der Parklast und der Sanierung der Verteilerleitungen kann es direkt in das neue System integriert werden, ohne dass ein Austausch der Gesamtausr\u00fcstung erforderlich ist, und verf\u00fcgt \u00fcber eine gute Skalierbarkeit.<\/p>\n<p>Q2: Ist bei Hochleistungsmodellen, die \u00fcber einen langen Zeitraum ununterbrochen arbeiten, die Sicherheitsschutzkonstruktion vollst\u00e4ndig?<br \/>\nA2: Es ist mit mehreren Schutzstrukturen ausgestattet, und die \u00f6lgek\u00fchlte K\u00fchlpufferleistung ist ausgezeichnet Es kann momentane Lastschwankungen puffern und h\u00e4ufige Probleme wie \u00dcberlastung und \u00dcberhitzung vermeiden, was den industriellen Standards f\u00fcr eine langfristige sichere Stromnutzung entspricht.<\/p>\n<p>F3: Was sind im Vergleich zu Modellen mit mittlerer und kleiner Kapazit\u00e4t die Hauptvorteile \u00f6lgek\u00fchlter Ger\u00e4te mit gro\u00dfer Kapazit\u00e4t?<br \/>\nA3: Es verf\u00fcgt \u00fcber eine st\u00e4rkere zentrale Lasttragf\u00e4higkeit und eine einzelne Einheit kann einen gro\u00dfen Bereich f\u00fcr die Stromversorgung abdecken, wodurch die Anzahl der Ausr\u00fcstungs- und Landinvestitionen reduziert wird und die Gesamtverteilungskosten niedriger sind, wodurch es sich besser f\u00fcr eine einheitliche Stromversorgungsplanung eignet gro\u00dfe Gebiete.<\/p>\n<div>\n<div>\n<div class=\"product-spec-table\">\n<table>\n<caption>20-kV-\u00d6l-Transistor-Energieeffizienzspezifikationen<\/caption>\n<thead>\n<tr>\n<th>Nennkapazit\u00e4t (kVA)<\/th>\n<th>HV-Nennspannung (kV)<\/th>\n<th>HV-Zapfbereich<\/th>\n<th>Nennspannung (kV) des LV<\/th>\n<th>Vektorgruppe<\/th>\n<th>Leerlaufverlust der Stufe 1 (kW)<\/th>\n<th>Lastverlust der Stufe 1 (kW)<\/th>\n<th>Leerlaufverlust der Stufe 2 (kW)<\/th>\n<th>Lastverlust der Stufe 2 (kW)<\/th>\n<th>Leerlaufverlust der Stufe 3 (kW)<\/th>\n<th>Lastverlust der Stufe 3 (kW)<\/th>\n<th>Kurzschlussimpedanz (%)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>30<\/td>\n<td>20<\/td>\n<td>\u00b15%<\/td>\n<td>0.4<\/td>\n<td>Dyn11 \/ Yzn11 \/ Yyn0<\/td>\n<td>0.08<\/td>\n<td>0.621\/0.594<\/td>\n<td>0.08<\/td>\n<td>0.690\/0.660<\/td>\n<td>0.1<\/td>\n<td>0.690\/0.660<\/td>\n<td>5.5<\/td>\n<\/tr>\n<tr>\n<td>50<\/td>\n<td>20<\/td>\n<td>\u00b15%<\/td>\n<td>0.4<\/td>\n<td>Dyn11 \/ Yzn11 \/ Yyn0<\/td>\n<td>0.104<\/td>\n<td>0.909\/0.864<\/td>\n<td>0.104<\/td>\n<td>1.010\/0.960<\/td>\n<td>0.13<\/td>\n<td>1.010\/0.960<\/td>\n<td>5.5<\/td>\n<\/tr>\n<tr>\n<td>68<\/td>\n<td>20<\/td>\n<td>\u00b15%<\/td>\n<td>0.4<\/td>\n<td>Dyn11 \/ Yzn11 \/ Yyn0<\/td>\n<td>0.12<\/td>\n<td>1.080\/1.040<\/td>\n<td>0.12<\/td>\n<td>1.200\/1.150<\/td>\n<td>0.15<\/td>\n<td>1.200\/1.150<\/td>\n<td>5.5<\/td>\n<\/tr>\n<tr>\n<td>80<\/td>\n<td>20<\/td>\n<td>\u00b15%<\/td>\n<td>0.4<\/td>\n<td>Dyn11 \/ Yzn11 \/ Yyn0<\/td>\n<td>0.144<\/td>\n<td>1.290\/1.230<\/td>\n<td>0.144<\/td>\n<td>1.440\/1.370<\/td>\n<td>0.18<\/td>\n<td>1.440\/1.370<\/td>\n<td>5.5<\/td>\n<\/tr>\n<tr>\n<td>100<\/td>\n<td>20<\/td>\n<td>\u00b15%<\/td>\n<td>0.4<\/td>\n<td>Dyn11 \/ Yzn11 \/ Yyn0<\/td>\n<td>0.16<\/td>\n<td>1.560\/1.490<\/td>\n<td>0.16<\/td>\n<td>1.730\/1.650<\/td>\n<td>0.2<\/td>\n<td>1.730\/1.650<\/td>\n<td>5.5<\/td>\n<\/tr>\n<tr>\n<td>125<\/td>\n<td>20<\/td>\n<td>\u00b15%<\/td>\n<td>0.4<\/td>\n<td>Dyn11 \/ Yzn11 \/ Yyn0<\/td>\n<td>0.192<\/td>\n<td>1.870\/1.780<\/td>\n<td>0.192<\/td>\n<td>2.080\/1.980<\/td>\n<td>0.24<\/td>\n<td>2.080\/1.980<\/td>\n<td>5.5<\/td>\n<\/tr>\n<tr>\n<td>160<\/td>\n<td>20<\/td>\n<td>\u00b15%<\/td>\n<td>0.4<\/td>\n<td>Dyn11 \/ Yzn11 \/ Yyn0<\/td>\n<td>0.232<\/td>\n<td>2.290\/2.180<\/td>\n<td>0.232<\/td>\n<td>2.540\/2.420<\/td>\n<td>0.29<\/td>\n<td>2.540\/2.420<\/td>\n<td>5.5<\/td>\n<\/tr>\n<tr>\n<td>200<\/td>\n<td>20<\/td>\n<td>\u00b15%<\/td>\n<td>0.4<\/td>\n<td>Dyn11 \/ Yzn11 \/ Yyn0<\/td>\n<td>0.272<\/td>\n<td>2.700\/2.570<\/td>\n<td>0.272<\/td>\n<td>3.000\/2.860<\/td>\n<td>0.34<\/td>\n<td>3.000\/2.860<\/td>\n<td>5.5<\/td>\n<\/tr>\n<tr>\n<td>250<\/td>\n<td>20<\/td>\n<td>\u00b15%<\/td>\n<td>0.4<\/td>\n<td>Dyn11 \/ Yzn11 \/ Yyn0<\/td>\n<td>0.32<\/td>\n<td>3.170\/3.020<\/td>\n<td>0.32<\/td>\n<td>3.520\/3.350<\/td>\n<td>0.4<\/td>\n<td>3.520\/3.350<\/td>\n<td>5.5<\/td>\n<\/tr>\n<tr>\n<td>315<\/td>\n<td>20<\/td>\n<td>\u00b15%<\/td>\n<td>0.4<\/td>\n<td>Dyn11 \/ Yzn11 \/ Yyn0<\/td>\n<td>0.384<\/td>\n<td>3.79\/3.61<\/td>\n<td>0.384<\/td>\n<td>4.21\/4.01<\/td>\n<td>0.48<\/td>\n<td>4.21\/4.01<\/td>\n<td>5.5<\/td>\n<\/tr>\n<tr>\n<td>400<\/td>\n<td>20<\/td>\n<td>\u00b15%<\/td>\n<td>0.4<\/td>\n<td>Dyn11 \/ Yzn11 \/ Yyn0<\/td>\n<td>0.456<\/td>\n<td>4.47\/4.26<\/td>\n<td>0.456<\/td>\n<td>4.97\/4.73<\/td>\n<td>0.57<\/td>\n<td>4.97\/4.73<\/td>\n<td>5.5<\/td>\n<\/tr>\n<tr>\n<td>500<\/td>\n<td>20<\/td>\n<td>\u00b15%<\/td>\n<td>0.4<\/td>\n<td>Dyn11 \/ Yzn11 \/ Yyn0<\/td>\n<td>0.544<\/td>\n<td>5.35\/5.09<\/td>\n<td>0.544<\/td>\n<td>5.94\/5.66<\/td>\n<td>0.68<\/td>\n<td>5.94\/5.66<\/td>\n<td>5.5<\/td>\n<\/tr>\n<tr>\n<td>630<\/td>\n<td>20<\/td>\n<td>\u00b15%<\/td>\n<td>0.4<\/td>\n<td>Dyn11 \/ Yzn11 \/ Yyn0<\/td>\n<td>0.648<\/td>\n<td>6.140<\/td>\n<td>0.648<\/td>\n<td>6.82<\/td>\n<td>0.81<\/td>\n<td>6.82<\/td>\n<td>6.0<\/td>\n<\/tr>\n<tr>\n<td>800<\/td>\n<td>20<\/td>\n<td>\u00b15%<\/td>\n<td>0.4<\/td>\n<td>Dyn11 \/ Yzn11 \/ Yyn0<\/td>\n<td>0.784<\/td>\n<td>7.430<\/td>\n<td>0.784<\/td>\n<td>8.25<\/td>\n<td>0.98<\/td>\n<td>8.25<\/td>\n<td>6.0<\/td>\n<\/tr>\n<tr>\n<td>1000<\/td>\n<td>20<\/td>\n<td>\u00b15%<\/td>\n<td>0.4<\/td>\n<td>Dyn11 \/ Yzn11 \/ Yyn0<\/td>\n<td>0.92<\/td>\n<td>10.200<\/td>\n<td>0.92<\/td>\n<td>11.3<\/td>\n<td>1.15<\/td>\n<td>11.30<\/td>\n<td>6.0<\/td>\n<\/tr>\n<tr>\n<td>1250<\/td>\n<td>20<\/td>\n<td>\u00b15%<\/td>\n<td>0.4<\/td>\n<td>Dyn11 \/ Yzn11 \/ Yyn0<\/td>\n<td>1.1<\/td>\n<td>11.900<\/td>\n<td>1.1<\/td>\n<td>13.2<\/td>\n<td>1.38<\/td>\n<td>13.20<\/td>\n<td>6.0<\/td>\n<\/tr>\n<tr>\n<td>1600<\/td>\n<td>20<\/td>\n<td>\u00b15%<\/td>\n<td>0.4<\/td>\n<td>Dyn11 \/ Yzn11 \/ Yyn0<\/td>\n<td>1.33<\/td>\n<td>14.400<\/td>\n<td>1.33<\/td>\n<td>16<\/td>\n<td>1.66<\/td>\n<td>16.00<\/td>\n<td>6.0<\/td>\n<\/tr>\n<tr>\n<td>2000<\/td>\n<td>20<\/td>\n<td>\u00b15%<\/td>\n<td>0.4<\/td>\n<td>Dyn11 \/ Yzn11 \/ Yyn0<\/td>\n<td>1.56<\/td>\n<td>17.200<\/td>\n<td>1.56<\/td>\n<td>19.1<\/td>\n<td>1.95<\/td>\n<td>19.10<\/td>\n<td>6.0<\/td>\n<\/tr>\n<tr>\n<td>3000<\/td>\n<td>20<\/td>\n<td>\u00b15%<\/td>\n<td>0.4<\/td>\n<td>Dyn11 \/ Yzn11 \/ Yyn0<\/td>\n<td>1.87<\/td>\n<td>20.000<\/td>\n<td>1.87<\/td>\n<td>22.2<\/td>\n<td>2.34<\/td>\n<td>22.20<\/td>\n<td>6.0<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Dieser Leistungstransformator mit gro\u00dfer Kapazit\u00e4t ist speziell f\u00fcr gro\u00dfe Industriest\u00fctzpunkte, industrielle Neust\u00e4dte und regionale zentralisierte Stromversorgungsprojekte konzipiert. Diese Projekte verf\u00fcgen in der Regel \u00fcber gro\u00dfe Stromverbrauchsgrundlagen und konzentrierte Lasten.<\/p>","protected":false},"featured_media":683,"template":"","meta":{"rank_math_title":"2000 kVA 20 kV Oil-Immersed Power Transformer | Heavy Duty","rank_math_description":"2000 kVA 20 kV Oil-Immersed Power Transformer for industrial bases, mines and new energy projects, with full-load stability and a sealed protective enclosure.","rank_math_canonical_url":"","rank_math_focus_keyword":"2000 kVA 20 kV Oil-Immersed Power Transformer"},"product_brand":[],"product_cat":[29],"product_tag":[],"class_list":["post-898","product","type-product","status-publish","has-post-thumbnail","product_cat-oil-immersed-transformers","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/www.byqpower.com\/de\/wp-json\/wp\/v2\/product\/898","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.byqpower.com\/de\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.byqpower.com\/de\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.byqpower.com\/de\/wp-json\/wp\/v2\/media\/683"}],"wp:attachment":[{"href":"https:\/\/www.byqpower.com\/de\/wp-json\/wp\/v2\/media?parent=898"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.byqpower.com\/de\/wp-json\/wp\/v2\/product_brand?post=898"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.byqpower.com\/de\/wp-json\/wp\/v2\/product_cat?post=898"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.byqpower.com\/de\/wp-json\/wp\/v2\/product_tag?post=898"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}